Dental Surgical Kit
|
Submerged Kit Submerged implant kit is a comprehensive set of implants which are necessary for dental implant surgical procedure. Our submerged implant kit consists of basic drill, final drill, reamer and prosthetic. Basic drill included in submerged implant kit determines initial entry point on the cortical bone. Final drill has an excellent drilling capability provided by optimal design of the tips. Reamer creates spaces for upper part of fixtures for easy implantation, and prosthetic is used when implanting fixtures. There are many models of implant devices. Check our website for our submerged implant kit. |
![]() |
How to Open the Package |
![]() |
|||
1. Check the size of fixture and pull out the product from the box. | 2. Rip off the paper on plastic case and pull out the ampoule. | 3. Hold plastic ampoule and rotate the cap to open. | 4. Check inside of fixture |
![]() |
|||
5. Pull out mountless driver carefully after it firmly combined with fixture by moving moultless driver right and left direction in the fixture. | 6. Implantation (Use CSM mountless driver softly in right and left way till it firmly combined with fixture). | 7. Hold up the ampoule cap and remove cap cover. | 8. Use CSM torx driver and connect the screw and tighten coupling of the cover screw into the fixture. |
Instruction For USE 1. Product Description The CSM Submerged Implant System includes various one-stage xtures and two-stage xtures made of titanium. These implants are inserted into the upper and/or lower jawbone and served as a tooth root replacement providing a stable foundation for restorations. 2. Precautions Surgical technique for endosseous dental xture implant requires special and complex procedures. Formal training for xture placement is recommended. Important : Determine local anatomy and suitability of the available bone for xture placement. Thorough screening of prospective xture must be performed. Panoramic and periapical radiograph for visual inspection are essential to determine anatomical landmarks, occlusal condition, periodontal status and adequacy of bone. Lateral cephalometric radiographs, computerized axial tomograghy and tomogram could be instructive. Appropriate radiography, direct palpation and visual inspection of the xture site are necessary for planning or treatment prior to use xtures. 3. Directions for use The surgical procedure should be done under aseptic condition with specially designed sterile surgical instruments. The sterilized implants have to be delivered precisely from package to preparation site. An electrical surgical drilling system with internal or external irrigation is recommended. Prescribed drilling sequences (Guide drill – Pre-nal drill - Final drill) or combination of surgical tools with 70Ncm torque power should be followed to make a hole in the jawbone and to place a xture. In case of Hard Bone(D1) please use CSM D1 Drill or the drill of next diameter. Parallel Pin is used for measuring the direction and the depth of the hole. Fixture in the ampul should be placed up by using Mountless Driver and be planted into the bone. Handpiece or Ratchet Wrench is usable to plant. Insertion depth of CSM xture shall be 0.2mm below than the bone level. When the xture is fully seated, carefully remove Mountless Driver and place Cover Screw or Healing Abutment on the xture. Then close tissue ap and suture it. The healing period will be 45~90days for lower jaw, 90~180days for upper jaw. (Don't lost balance in drilling work during operation) 4. Usage and Storage • This product is disposable. • It should not be reused. • All the product package should be stored at low humidity and room temperature condition 5. Caution • Surgical Complications : Implant procedure has risks such as localized swelling, dehiscence, temporary pain, edema, hematoma or bleeding. Numbness of the lower lip and jaw after mandible surgery and tissue beside the nose after maxilla surgery is a possible side-eect. It is a temporary nature, though the numbness lasts permanently very rarely. Gingival-mucosal (gum tissue) ulceration, tissue reaction, or infection may occur but it generally responds to local care. • After the procedure of implant treatment could be found swollenness of a specic part, rupture, temporary palpate sensitiveness, an edema, hematoma, bleeding. • Insensibility of lower jaw and lip, some side eects relating around the nose from maxillary sinus treatment may occur that is mostly temporary but rarely permanent paralysis could appear. • Contraindications : Fixture should not be placed in case where the remaining jaw bone is too diminished to provide adequate width and height to surround the implant. Lack of osseointegration or subsequent implant failure may occur in cases insucient bone available, poor bone quality, poor oral hygiene, heavy smoking, or under medical conditions such as blood disorders, infected HIV virus or uncontrolled diabetes. • Warnings (Wornings for possible side eects from the usage of medical devices) : As xture surgery and dental restoration involve complex surgical procedures, for safe and eective use of xtures, specialized training is strongly suggested. Improper patient selection and technique can cause the xture failure and/or loss of supporting bone. Wobble of xture, bone loss, or chronic infection may cause xture failure. If the xture becomes contaminated by the patient’s body uids in any way, the xture cannot be used in other patient. Do not splint or bridge with natural tooth. Excessive force on the xture will cause metal fatigue and can cause xture fracture. Single stand or by xtures are recommended. • Interaction : Dental xtures are designed only for its use and must not be altered and converted in any way. The use of electro-surgical or laser surgical instruments around metallic xtures and their abutments is not recommended due to the risk of electric shock and/or heat burn. • Usage for the aged or a pregnant woman : The aged, a pregnant woman, growth phase, an obese patient or a patient who had other case history shall be considered to perform an operation. • Warnings for application : A surgeon shall be followed instruction of the procedure for high success rate of implant surgery. Advert to not damage on nerves, diagnose concavity on lingual side of the submaxillary bone for preventing perforation of the submaxillary bone. Do not put over torque for preventing bone crack. • Caution of safety accidents : Take any possible stus away as combustibility materials or unsterilization devices from a patient and a surgeon. Suitable location Use the xtures as [Ø3.6], [Ø4.0] for incisor(1,2,3) or premolar(4), [Ø4.4], [Ø4.8] for premolar(5) or molar(6,7). Package Check/Management • CSM Fixtures are sterilized with gamma radiation. If the sterilized package are/were damaged or opened, please do not use the products. • Do not use the product after the expiry date written on the package. • Unpacked product by users cannot be returned to the manufacturer or distributor. • Manufacturer or distributor has no responsibility of any following matters for the products re-sterilized by users. 1. After operation, Immediately all the tools should be soaked in alcohol and removed bloodstain and any visible debris with a soft bristle brush. *Before wash and sterilizing the Torque Wrench, Please disassemble the Wrench. *Caution. Do not use hydrogen peroxide to prevent discoloration of Laser Mark ing and Coating. 2. The tools should be washed again with distilled water or running water. 3. Dry the tools completely with dry cloth or air. 4. Return the instruments to the appropriate locations in the surgical tray. 5. Sterilize with Autoclave and store the kit at room temperature. (temperature:132°C, duration : 15min, Steam pressure:1.5) * Notes The CSM surgical kit has a one year warranty and the maximum usage of the drills is 50 times. |
The person in charge
Sungam ChoAddress
47 Gyeongdae-ro 17-gil, Buk-gu, Daegu (41566)QR cord
Please enter the text on the left image to prevent automatic input.
0 / 4000