Go to body Contents
CSM Implant

CSM IMPLANT Submerged System Surgical KIT(I,II,III), Dental Implant Instruments FDA / ISO / CE

  • Payment
    GN , L/C(sight) , T/T
  • MOQ
    1 Set
  • Supply Ability
    10,000 Set per Month
  • Supply Details
    Customization Sample Order

    Negotiable/ Depends on quantity / If you want to buy in bulk, please contact me.

  • Country of sale
    Asia, Americas, Middle East, Europe, World Wide
  • PRICE
    • FOB

      USD 450.00

      (10 Set)

ITEM SPECIFICS

  • Brand
    CSM Implant
    Model Dental Surgical Kit (Suberged 3)
  • origin
    Republic of Korea
  • Size(Capacity)
    There are various sizes
  • Weight
    360g
  • Material
    Grade Ⅳ titanium
  • Function
    This product is disposable.
  • Features
    All the product package should be stored at low humidity and room temperature condition
  • Gender
    None
  • age-appropriate
    All ages
  • Expiry Date
    No Exporation Date.


PRODUCT DESCRIPTION

CSM IMPLANT Submerged System Surgical KIT
Description
Submerged implant kit is a comprehensive set of implants which are necessary for dental implant surgical procedure.
Our submerged implant kit consists of basic drill, final drill, reamer and prosthetic. Basic drill included in submerged implant kit determines initial entry point on the cortical bone. Final drill has an excellent drilling capability provided by optimal design of the tips. Reamer creates spaces for upper part of fixtures for easy implantation, and prosthetic is used when implanting fixtures. There are many models of implant devices. Check our website for our submerged implant kit.

The CSM Submerged Implant System includes various one-stage xtures and two-stage xtures made of titanium. These implants are inserted into the upper and/or lower jawbone and served as a tooth root replacement providing a stable foundation for restorations.
Dental Submerged Kit

Submerged Ⅱ Kit

Submerged III Kit

CSM Implant System Instructions for Use
Precautions

Surgical technique for endosseous dental xture implant requires special and complex procedures. Formal training for xture placement is recommended. Important : Determine local anatomy and suitability of the available bone for xture placement. Thorough screening of prospective xture must be performed. Panoramic and periapical radiograph for visual inspection are essential to determine anatomical landmarks, occlusal condition, periodontal status and adequacy of bone. Lateral cephalometric radiographs, computerized axial tomograghy and tomogram could be instructive. Appropriate radiography, direct palpation and visual inspection of the xture site are necessary for planning or treatment prior to use xtures.
Directions for use

The surgical procedure should be done under aseptic condition with specially designed sterile surgical instruments. The sterilized implants have to be delivered precisely from package to preparation site. An electrical surgical drilling system with internal or external irrigation is recommended. Prescribed drilling sequences (Guide drill – Pre-nal drill - Final drill) or combination of surgical tools with 70Ncm torque power should be followed to make a hole in the jawbone and to place a xture. In case of Hard Bone(D1) please use CSM D1 Drill or the drill of next diameter. Parallel Pin is used for measuring the direction and the depth of the hole. Fixture in the ampul should be placed up by using Mountless Driver and be planted into the bone. Handpiece or Ratchet Wrench is usable to plant. Insertion depth of CSM xture shall be 0.2mm below than the bone level. When the xture is fully seated, carefully remove Mountless Driver and place Cover Screw or Healing Abutment on the xture. Then close tissue ap and suture it. The healing period will be 45~90days for lower jaw, 90~180days for upper jaw. (Don't lost balance in drilling work during operation)
Usage and Storage

• This product is disposable.
• It should not be reused.
• All the product package should be stored at low humidity and room temperature condition
Caution

• Surgical Complications : Implant procedure has risks such as localized swelling, dehiscence, temporary pain, edema, hematoma or bleeding. Numbness of the lower lip and jaw after mandible surgery and tissue beside the nose after maxilla surgery is a possible side-eect. It is a temporary nature, though the numbness lasts permanently very rarely. Gingival-mucosal (gum tissue) ulceration, tissue reaction, or infection may occur but it generally responds to local care.
• After the procedure of implant treatment could be found swollenness of a specic part, rupture, temporary palpate sensitiveness, an edema, hematoma, bleeding.
• Insensibility of lower jaw and lip, some side eects relating around the nose from maxillary sinus treatment may occur that is mostly temporary but rarely permanent paralysis could appear.
• Contraindications : Fixture should not be placed in case where the remaining jaw bone is too diminished to provide adequate width and height to surround the implant. Lack of osseointegration or subsequent implant failure may occur in cases insucient bone available, poor bone quality, poor oral hygiene, heavy smoking, or under medical conditions such as blood disorders, infected HIV virus or uncontrolled diabetes.
• Warnings (Wornings for possible side eects from the usage of medical devices) : As xture surgery and dental restoration involve complex surgical procedures, for safe and eective use of xtures, specialized training is strongly suggested. Improper patient selection and technique can cause the xture failure and/or loss of supporting bone. Wobble of xture, bone loss, or chronic infection may cause xture failure. If the xture becomes contaminated by the patient’s body uids in any way, the xture cannot be used in other patient. Do not splint or bridge with natural tooth. Excessive force on the xture will cause metal fatigue and can cause xture fracture. Single stand or by xtures are recommended.
• Interaction : Dental xtures are designed only for its use and must not be altered and converted in any way. The use of electro-surgical or laser surgical instruments around metallic xtures and their abutments is not recommended due to the risk of electric shock and/or heat burn.
• Usage for the aged or a pregnant woman : The aged, a pregnant woman, growth phase, an obese patient or a patient who had other case history shall be considered to perform an operation.
• Warnings for application : A surgeon shall be followed instruction of the procedure for high success rate of implant surgery. Advert to not damage on nerves, diagnose concavity on lingual side of the submaxillary bone for preventing perforation of the submaxillary bone. Do not put over torque for preventing bone crack. • Caution of safety accidents : Take any possible stus away as combustibility materials or unsterilization devices from a patient and a surgeon.
 
Other Products

R&D CERTIFICATE

  • Certificate of patent 
    Korean Intellectual Property Office 
    08.01.15 
    인증서보기

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Letter of Credit : L/C(sight)
  • GN
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : Manager

SHIPPING

Shipping from : Republic of Korea
  • 47 Gyeongdae-ro 17-gil, Buk-gu, Daegu (41566)
CSM Implant
  • The person in charge

    Sungam Cho
  • Address

    47 Gyeongdae-ro 17-gil, Buk-gu, Daegu (41566)

QR cord

CSM Implant
Introduction
Thank you for visiting CSM Implant! Welcome to CSM Implant and thank you for visiting our web site. Since its foundation in 2000, CSM Implant has provided high quality dental products and service with the clean and safe production environment. Founder/President Sungam Cho who is a professor of, department of prosthodontics, college of Dentistry, Kyung-pook national University, which is one of the leading national universities in Korea. All products are developed by many of experienced dentists and dental specialists in dental implant industry. Our energetic and passionate team members keep discovering the innovation in dental implant system. CSM’s top priority is to meet both dentists’ and patients’ satisfaction with the better implant system based on long-term research and development experience. CSM Implant aims to produce not only superior in quality, but also reasonable in price with user friendly service. All of our uniquely designed dental implants minimize the possible damage on teeth such as loss of surrounding teeth, migration of teeth and teeth structure loss. We will continuously develop clean and safe implant system with our sincere heart and will consistently pursue our number one object which is to meet user satisfaction in terms of esthetic and functional aspect. Thank you for taking your interests and time for CSM Implant, we hope to hear from you soon.
  • Business Type :
    Manufacturer
  • Main Product :
    Implant product
  • Established :
    2000-01-24
  • Total Annual Revenue :
  • Total Employees :
    11~50 people

R&D CERTIFICATE

COMPANY ENVIRONMENT

Please suggest a variety of your ideas such as design, impact, enhancements, etc

Captcha Required
   

Please enter the text on the left image to prevent automatic input.

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

Max 1 files, 20Mb limit per attachment

Captcha Required
   

Please enter the text on the left image to prevent automatic input.

At least 10~1000 characters.

0/ 1000

TRADE EXPERIENCE

  • Total revenue
  • Total export revenue (previous year in USD)
    3
  • Number of foreign trade employees
    11~50 people

COMPARISON TO SIMILAR ITEMS more

  • No Items
supplier level
PLATINUMPLATINUM
CSM Implant Seller's Store
Seller's Store url
  • Response Level
      41% ~ 50%
  • Supplier Level
      Less than 100 million (KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • CSM IMPLANT Submerged Implant System
  • Submerged Implant2