Compressor Auto Drain Valve
Compressor auto drain valve manufacturer
Description
The valve is designed to automatically open and close. When the pressure drops below 4kgf, the valve opens. When the pressure reaches 5kgf, the valve closes.
Unlike conventional condensate valves installed in piping, it is installed in the drain port of the air tank to drain the condensate initially. -Maximize the functional efficiency of air filters and air dryers by draining condensate even before passing the piping
Features our compressor auto drain valve
1.The compressor auto drain valve is a pure mechanical valve that opens and closes only with the compressor's own pressure
2.The features of the compressor auto drain valve is designed to automatically open when the air pressure of the compressor falls below about 5kgf and release air pressure and moisture, and it is a valve that automatically closes when the air pressure is more than 6kgf.
3.Existing commercial auto drain valves(electronic type) are mainly installed in pipes and are opened when moisture is accumulated to a certain quantity, and the auto drain valve(electronic type) for installing the drain hole of the air tank is also frequently clogged by rust sludge in the tank, so it is necessary to disassemble and clean from time to time, unlike the compressor auto drain valve in one body it has a advantage that there is no such hassle
4.The compressor auto drain valve has a failure rate close to 0%.
Features of our air compressor auto drain valve system
Compressor auto drain valve product is suitable for 24 hours operation of air compression system, and it operates only when the compressor system is operated and releases condensate water for a certain period of time, since the air cylinder forcibly releases condensate water for a certain time set by the timer by using the compressor's own pressure, it prevents condensate water from accumulating in the air tank of the piston compressor or the receiver tank of the screw. Due to this, it minimizes the amount of moisture flowing into the air line piping, and even if you do not install expensive air filters other than expensive system, air dryer, in the air piping, you can get a great effect by connecting only a few low-cost automatic air filters.
Precautions for installing the compressor auto drain valve
1.Before installing the condensate automatic discharge valve of the compressor, install the rust sludge in the compressor pressure tank after opening the cock 2 to 3 times at a pressure of 7kgf or more to completely remove the rust sludge in the pressure tank. Minor rust sludge generated after that is automatically discharged.
2.If large particles of rust sludge get caught in the disk of the compressor auto drain valve, the valve is not completely closed, so a minute leak occurs in the water discharge nozzle. In this case, as it is not a malfunction, so if you repeat opening and closing 2 to 3 times for 2 to 3 seconds as shown in , rust sludge is discharged and the valve is completely closed
Installation order of the compressor auto drain valve
1.Completely remove rust sludge in the pressure tank of the compressor system.
2.Remove the cock attached to the compressor.
3.Install the elbow which is a part of the condensate auto drain valve of the compressor by winding it with Teflon tape.
Install to the air tank in the direction of the long part of the elbow.
4.Install the handle of the compressor auto drain valve in the direction as shown in [Figure 2].
5.Next, install the compressor auto drain valve in the direction as shown in [Figure 2].
6.If the system(system) is installed outside, it is safe to wrap it with insulating material as the valve disk may freeze and may operate unstably.
7.Be careful when wrapping Teflon tape on each thread. If it is wound incorrectly, the Teflon may enter the inside diameter and jam the disk of the compressor auto drain valve, which may cause a malfunction.
Installation of the auto drain valve
Other Products