Product name: Digital thermostat
Product Name: Digital Automatic Thermostat
Model name: DH-51
Model Name: DH-51
TYPE: Digital
TYPE: Digital Method
Power used: AC 85V to AC 265V
Power supply: AC 85V to AC 265V
Number of circuits: 0'C to 99'C
Number of Circuits: 0'C to 99'C
Maximum output: 1 circuitxx
Maximum output: 1 circuit xx
Panel Usage: 4kw (20A)
Panel usage: 4kw (20A)
Construction type: Embedded (exposed type)
Construction Type: Built-in (exposure type)
Driving system: Sensor system / Timer system
Drive System: Sensor system/timer system
Safety: Overpassenger protection sensor (optional)\
Safety device: Overheating event sensor (optional) \
Appearance: Non-flammable ABS
External material: Flame-retardant ABS
Appearance size: 70(W) * 120(H) * 38(D)
External size: 70 (W) * 120 (H) * 38 (D)
- DH - 51 (Barley) User's Guide
-Manual Instrumentation for Using DH-51 (barley)
The temperature control sensor can be detached and attached. Sensor control system when connecting sensors Timer system when not connected to sensors
Sensor control methods when the sensor is connected Timer method when the sensor is not connected
(Forced by time 0 N/OFF)
(Forced 0N/off by time)
When the temperature sensor is short-circuited, it is forced to operate on/off mode by time.
When the tempature sensor is short-circuited, it is operated by force by force by time.
If you turn on the power switch, the current temperature is displayed in the display window.
When you ON the power switch, the current tempature is displayed on the display window.
Set the desired temperature with the up/down switch (green lamp illumination).
Set the desired template with the up/down switch (green lamp light)
The output (red lamp) turns on when the load is electrically charged.
When the load flows electricity, the output (red lamp) is turned on.
When the set temperature is reached, the red lamp turns off and automatically maintains the set temperature.
When it attached the set tempature, the red lamp turns off and keeps the set tempature automatic.
In case of malfunction due to program error of the thermostat, unplug the power cord and reconnect it after 10 seconds.
In case of solution due to a program error of the program, unplug the power code and connect it after 10 seconds.
All applications will be initialized.
All programs are initialized.
Please unplug the power cord when you are away or out of the power cord must be unplugged.
Be sure to unplug the power cord when not in use or when you are away.
When using the thermostat, make sure to keep the proper amount.
Be sure to keep the alternative account when using the thermostat.
Jeon Won Boo
Power supply part
1. Rated input method: 85VAC to 265VAC
1. Rated input method: 85VAC to 265VAC
2. Driving method: Electronic
2. Drive system: Electronic
3. Maximum output: Circuit: 3 kw, auxiliary: 3 kw (220 V reference)
3. Maximum output: Circuit: 3kw, Auxiliary: 3kw (220V standard)
4. Load 1) Number of circuits 2 (one circuit + auxiliary circuit)
4. Load 1) Circuit number 2 (1 Circuit + auxiliary circuit)
2) Maximum capacity once: 12A, auxiliary: 12A (resistance load)
2) Maximum capacity 1 circuit: 12A, auxiliary: 12A (resistance load)
Precision
Precision
1.+-1'C ; 1'C condition of change per 30 seconds
1.+-1'C; 1'C change condition per 30 seconds
movement
Motion
1. Power input indication: [LCD] ON
1. Power on display: [LCD] ON
2. Output Display: [LCD] BAR Behavior
2. Indication of output: [LCD] BAR operation
3. Temperature range: 0'C to 80'C\
3. Temperature range: 0'C to 80'C\
4. Remote control status: No
4. Remote control: None
Sensor
Sensor
1.Type: NTC epoxy moulding
1.Type: NTC Epoxy Molding
2. Precision: 3%.
2. Precision: 3%.
25'C Rated Resistance: 5
3. 25'Cated list: 5
4. Quantity: 1EA for temperature sensing
4. Quantity: 1EA for tempature detection
a safety device
Safety device
1. Sensor's short circuit: open circuit:EO/stage mode switching, short circuit ; ES error
1.Short circuit/short circuit of sensor: Disconnection: EO/step mode changeover, short circuit; ES error
2. Overheat blocking function: Hughes blocking when 115'C is detected
2. Overheated cutoff function: Use block when 115'C is detected
3. Internal protection of the regulator: internal circuit protection shoes
3. Protection inside a controller: Use for internal circuit protection