TBD, Depend on quantity
EXW
USD 0.00 ~ 3,000.00
(1 ea)
Type | Differential (DPIT), Gauge/ Absolute (PIT), Level pressure (LIT), Flow Pressure (FIT), High Static pressure | |
Certificate | SIL2 (TUV, FMEDA), Ex d, Ex ia, ATEX, IEC, TR CU(EAC), DNV-GL, CE, RoHS2, KCs, IP66 | |
Feature | 4 to 20mA, Digital Signal, Loop Powered, HART 7, Fieldbus Foundation, Inert Oil, HAST-C, Monel, Tantal, Gold plate | |
High Accuracy+/- 0.04% of CS, Rangeability 100:1 turndown, Stability (+/- 0.125% URL for 60 months) External Buttons, 3 lines LCD display, Failure Mode, Trim, Unit changeable, Self Diagnostic Function |
||
Span | min. | DPT 0.0625 kPa , HS 0.65 kPa , GP 0.0625 kPa , AP 2.5 kPa |
max. | DPT 14,000 kPa , HS 2100 kPa , HS GP 40,000 kPa , GP 14,000 kPa , AP 2500 kPa | |
Static | max. | DPT 25 MPa , HS 32 MPa , HS GP 75 Mpa , GP 25 MPa , AP 2.5 MPa |
Application | Steam, Oil & Gas(Upstream, Downstream), PetroChemincal, Sticky liquid, High Static Pressure, Resistance Spiking Pressure, Oxygen, Hydrogen, Chlorine |
|
Points Features | DPT, FT, Low Pressure | High Static Pressure, External Stress | Direct Bottom Connection |
Type | Ex Field mount | Din Rail mount | Head mount |
Input | RTD (2, 3, 4 wires, a=0.00385), T/C (B, E, J, K, N, R, S, T), mV, ohm | ||
Feature | 4 to 20mA, Digital Signals, Loop Powered, HART 5, 7 | ||
RTD Stability for 24 months (+/- 0.12 % of reading or 0.15 degC whichever is greater) | |||
Certificate | Ex d, FM, ATEX, DNV, KCs | Ex ia, ATEX | |
Span | RTD : -200 to 650 deg C , T/C : - 200 to 1820 deg C | ||
Accuracy | Digital/ Analogue Accuracy of SPAN ( +/- 0.03%) + (Digital Accuracy / SPAN x 100) Digital Accuracy - RTD : max +/- 0.17 deg C , T/C : max +/- 0.77 deg C | ||
Ambient Temp. | -40 to 85 deg C | ||
Points Features | External Buttons, 3 lines LCD display, Failure Mode, Trim, Unit changeable | Self Diagnostic Function | Universal size, Ex ia |
MODEL | ALT6100 | ALT6200 | ALT6210 |
Type | Contact | Non-Contact | Non-Contact |
Technology | Guided Wave Radar | 6.3 Ghz Radar | 26 Ghz Radar |
Accuracy | +/- 3mm, +/- 0.03% of SC whichever is greater | +/- 10 mm | +/- 3 mm |
Feature | Rod, Coxial, Cable, High Pressure & Temperature | Horn antenna 3 ~ 8 inches Rod antenna available | Horn antenna 2, 3, 4 inches Seal antenna 3, 4 inches Encapsule, Parabolic antenna |
Certificate | Ex d, KCs, IP66/67 | ||
Range | 0.15 to 20 meter | 0.5 to 30 meter | 0.5 to 35 meter (special 70 meter) |
Application | Condition Low Viscosity, Less Emulsion or Foam | Swell, Wave, Noise, High Viscosity, Foam | Noise, High Viscosity, Foam, Less Wave |
Point Feature | Liquid Application | Wide Beam Angle | Narrow & Straight Beam Angle |
(Check the frequency related law on Open Tank application) |
The person in charge
YOUNG SOO KIMAddress
298-29 Gongdan-ro, Gunpo-si, Gyeonggi-do (15809)두온시스템
Please enter the text on the left image to prevent automatic input.
0 / 4000