1. This product is only applicable to battery VOLTA models manufactured by LG Energy Solutions, Ltd.
2. The charger is connected to the BMS of battery by CAN communication to control and
supports constant current mode(CC Mode) and constant voltage(CV Mode) of charging.
3. It takes a certain amount of time to reach the target current during CC Mode.
In CV Mode, the charger is charged based on voltage and finishs charging by the
charging termination conditions received from BMS.
4. Charging control is performed based on the limited voltage and current provided by
BMS in both CC Mode and CV Mode.
HOW TO USE
< Start of Charging >
1. Press the power switch (back of the cradle charger) to OFF (O-shape)
2. Connect the provided power cable to the power cable connector on the back of the charger.
3. Press the power switch (back of the cradle charger) to ON (I-shaped).
4. Open the cradle charger cover and press the charge switch once to turn on the charge.
5. Insert the battery into each charging port to start charging.
6. Verify that the LED status indicator and Dot Matrix indicator display normally.
(During normal charging, the LED status indicator flashes an orange or green light and the Dot Matrix indicates the amount of battery charged.)
< End of charging >
1. Press the charge ON/OFF button for at least 1.5 seconds to end the charge.
2. After full charge, Remove the battery from the charging port.
3. Press the power switch on the back of the charger to OFF (I-shape).
4. Disconnect the power cable from the connector of the cradle charger.
Power |
Rated power |
600W x 2ch |
Input Voltage |
AC 220V , 1Phase, 50/60Hz |
|
Output Voltage |
48V |
|
Output Current |
8.64A |
|
Enclosure |
Material |
PCB, CIRCUIT, PA66 |
Operating Tempature |
-20~60℃ |
|
Cooling |
Fan |
|
Dimension |
405x280x185 mm |
|
Weight |
6.5kgs |
|
Cable Length |
1270mm (±3.0%) |