Small Medical Waste incinerator
Overview
Compact incinerator which can burn medical waste(50kg/hr, 100kg/hr). This incinerator is suitable for mid-sized and smaller general hospitals. It can completely dispose of medical waste.
Features
Incineration Flow Chart
Design Criteria
Incinerated medical waste composition ratio
Sort of waste
|
Amounts of waste Incinerated (kg/hr)
|
Ratio Remark(%)
|
Human/Animal anatomical waste
|
6.0
|
12
|
Microbiological infectious waste
|
15.2
|
30.4
|
Non-anatomical infectious waste
|
8.4
|
16.8
|
General hospital waste
|
20
|
40
|
Total
|
50
|
100
|
Pollutants emission criteria
Pollutants
|
Design Standard
|
CO
|
Less than 100(12)ppm
|
NOx
|
Less than 100(12)ppm
|
Fine Dust
|
Less than 70(12) mg/Sm3
|
Exhausted fume
|
Less than 1 degree on the Ringelmann smoke chart
|
Incinerator Specifications
Model Name
|
KRM-20
|
KRM-500
|
KRM-1000
|
|
Furnace Capacity
|
20kg/hr
|
50kg/hr
|
100kg/hr
|
|
One-time Input Capacity
|
20-50kg
|
100-150kg
|
200-300kg
|
|
Volume
|
0.5m3
|
1.5m3
|
2.2m3
|
|
Installation Area
|
2000x2000mm2
|
4000x5000mm2
|
5000x6000mm2
|
|
Air Blower
|
15m3
|
30m3
|
45m3
|
|
Burner
|
Ignition Burner
|
4-8kg/hr
|
4-8kg/hr
|
4-8kg/hr
|
Secondary Burner
|
8-10kg/hr
|
10-20kg/hr
|
12-30kg/hr
|
The person in charge
Address
11B 10L, Namdong Idus. Complex, Namchon-dong 326, Seunggicheon-ro,Namdong-gu,Incheon, 인천광역시,Please enter the text on the left image to prevent automatic input.